Vacupor® TS-B2

VACUPOR® TS-B2-S with robust step sound protection board. 

VACUPOR® TS-B2-S is the building authorities approved "S-type" Vacuum Insulation Panel with recycling noise-reduction-sheet lining.

Rated value: 0,007 W/(m*K)

The German Institut for civil engineering (DIBt) granted the approval by the building authorities for VACUPOR® TS-B2-S under the certification number Z-23.11-1662. The approval is valid for construction applications DAD, DAA, DZ, DI, DEO, WAB, WAA, WH, WTR and WI according to standard DIN 4108-10, table 1 and for prefabricated façade panels with insulated glass character.

VACUPOR® TS-B2-S conforms to Baustoffklasse B2.
The test of behaviour in case of fire according DIN 4102-1, May 1998, Baustoffklasse B2; Testcertificate No. H.3-145/07 and H.3-146/07, was issued by the Forschungsinstitut für Wärmeschutz e.V. München.

VACUPOR® TS-B2-S (core material) is not flammable and is classified A1 according to DIN ISO EN 13501-1.

Due to the double-sided coverage of the vacuum panel with recycling noise-reduction-sheets, VACUPOR® TS-B2-S is especially suitable for floor insulation, where noise reduction and load distribution is required.

The fixing of the insulation is much easier, due to the possibility of bonding with commercially available adhesives.

Vacupor® TS-B2-S is available in one version with 4 mm thick coating on both sides.



Data sheet